SH2 Sample Holder
Available for Quote
SKU
ZSH2
The SH2 provides one axis of rotation about the centre of the manipulator and the second at 90° known as azimuthal rotation.
Two different offset positions available;
- a) The SH2E50 will provide move the sample away from the centre axis,
- b) The SH2R64 moves the sample position 64mm above the central axis.
As with all the manipulation range, this module is fully compatible for both the heating and cooling modules making it the perfect multidiscipline two axis sample mounting module.
Note: totally non-magnetic version are available.
Sample Holders - Basic Specifications | |||||||||
SH1 | SH1E50 | SH2 | SH2E50 | SH2R64 | SH2F | SH2RT | SM2T | SM2VT | |
Rotary Drive Required | RD1 | RD1 | RD2 | RD2 | RD2 | RD224 | RD2 | RD2 | RD2 |
Primary (R1) Rotation | |||||||||
No services | 360° | 360° | 360° | 360° | 360° | 360° | 360° | 360° | 360° |
With services | ±180° | ±180° | ±180° | ±180° | ±180° | ±180° | ±180° | ±180° | ±180° |
Azimuthal (R2) Rotation | |||||||||
Preset | ±180° | ±180° | |||||||
Variable | ±110° | ±110° | ±110° | ±180° | |||||
Tilt (R3) Rotation | ±110° | ±10° | ±10° | ||||||
Sample Offset | E | E | E | E | R | E | E | E | E |
Bare backplate (mm) | 9 to 12 | 9 to 50 | 9 to 12 | 9 to 50 | 54 to 64 | 9 to 12 | 5.5 to 9.5 | 5.5 to 7.5 | 5.5 to 7.5 |
Plain or heater unit (mm) | 0 to 3 | 0 to 41 | 0 to 3 | 0 to 41 | 60 to 66 | 0 to 3 | 0 to 2.5 | 0 to 2.5 | 0 to 2.5 |
Swept Radius | From | From | |||||||
No services (mm) | 25 | 25 (min) | 25 | 25 (min) | 54 to 64 | 25 | 31 | 35 | |
With all services (mm) | 38 | 38 (min) | 38 | 38 (min) | 54 to 64 | 38 | 44 | Variable | Variable |
Magnetic Permeability | Low | Low | Low | Low | Low | Low | Low | Normal | Normal |
'H' dimension (mm) | 66 | 66 | 66 | 66 | 66 | 103 | 66 | 66 | 66 |
Temperature Ranges | |||||||||
Resistive heater (HST) | 950 °C | 950 °C | 950 °C | 950 °C | 950 °C | 950 °C | 950 °C | 950 °C | 950 °C |
EB heater (EBH) | 1200 °C | 1200 °C | 1200 °C | 1200 °C | 1200 °C | 1200 °C | 1200 °C | 1200 °C | 1200 °C |
Cooling (LN) | -160 °C | -160 °C | -160 °C | -160 °C | -140 °C | -160 °C | -160 °C | -160 °C | -160 °C |
Approx. resolution per halfstep of RD motor | |||||||||
R1 rotation (stepper) | 0.01° | 0.01° | 0.01° | 0.01° | 0.01° | 0.01° | 0.01° | 0.01° | 0.01° |
R2 rotation (stepper) | - | - | 0.001° | 0.001° | 0.001° | 0.001° | - | - | - |
R3 rotation (stepper) | - | - | - | - | - | - | 0.001° | 0.0001° | 0.0001° |
Features
- Relative permeability is <1.005
- Low swept volume
- Samples of varying thickness can be rotated on axis
- Standard Sample axial Offset, 9 to 12mm (without heater)
- Sample axial offset with SH1E50 option 9 to 50mm (without heater)
- Primary (R1) Rotation with no services 360°
- Primary (R1) Rotation With services i.e.heating and cooling ±180°
- Swept Radius from 25mm to 38mm depending on additional modules being selected
- Residual Magnetism 10 milli Gauss
- Azimuthal (R2) rotation ±110°
Accepts the following options
- Resistive heater (HST) 950°C option
- EB heater (EBH) 1200°C option
- Cooling (ZLN) -160°C option
- 14mm plain accessory where heating/cooling is not required
- 25mm plain accessory where heating/cooling is not required